Torosgaz Kütahya Gas Project Rules
Torosgaz Kütahya Doğal Gaz Dağıtım Sanayi ve Ticaret A.Ş.. Provinces served: Kütahya. Group: Torosgaz. Rules: read from the company code
Calculation rules
| Service box → meter loss limit | 1 mbar |
|---|---|
| Meter → appliance loss limit | 0.8 mbar |
| Velocity limit (low pressure) | 6 m/s |
| Friction loss, steel | formula at all flows (23.2·R·Q^1.82/D^4.82, R = 0.6) |
| Efficiency in appliance flow | 90% at 70 kW and above |
| Isometric angle | 30° |
Code source
Torosgaz Binalar İçin Doğalgaz Tesisatı Teknik Esasları, s. 41–50
How to select it in GazPlan
Open the app and choose Kütahya as the province in the wizard or project panel; Torosgaz Kütahya Doğal Gaz Dağıtım Sanayi ve Ticaret A.Ş. is selected and the calculation uses these rules. Open the app
For information only; the distribution company's current code applies to projects.